The solenoid valve does not work after it is energized, what should I do?

2022-08-22

There are the following situations that the solenoid valve does not work after it is energized

Check the power wiring, if there is poor contact, rewire and connect the connector


Check the power supply voltage, if it is not in the working range, adjust to the normal position range

Check coil soldering, if desoldered, re-solder

Check the coil, if shorted, replace the coil

Check the working pressure differential, if it is not suitable, adjust the differential pressure or replace the commensurate solenoid valve

Check fluid temperature, if too high, replace solenoid valve commensurate

Check for impurities. If there are impurities that make the main spool and moving iron core of the solenoid valve stuck, clean it. If the seal is damaged, replace the seal and install a filter.

Check the solenoid valve liquid viscosity, if the clay is too large, the frequency is too high and the life is over, replace the product